Home | Vision | Staff | History | Contact Us
Fibre Specifications


Outdoor Fiber Cable  
Features and Benefits:
  • Quicker cable preparation and termination.
  • Cable water-blocking technology eliminates the need for traditional flooding compound, providing more efficient and craft-friendly cable preparation.
  • Available in multimode (62.5um, 50um) and single-mode.
  • Standard 3.0 mm buffer tube size reduces the number of access tools required by craftsperson.
  • Designed to isolate fibers from installation and environmental rigors.
  • Medium density PE jacket is rugged, durable, and easy to strip.
Applications:
  • Interbuilding backbones in aerial and duct installations.
Mechanical Specifications:
Maximum Tensile Loading: Installation: 2700N (600 lbf)
Long Term Installed: 890 N (200 lbf)
Operating Temperature: -40ºC to +70ºC
 
Fiber Count Number of Tubes Nominal Weight
Kg/Km
(lb/1000ft)
Nominal Outer Diameter
mm (in)
Minimum Bend Radius
Loaded
cm (in)
Installed
cm (in)
2 - 24 2 83 (56) 11.0 (0.4) 16.5 (6.5) 11 (4.3)
 
Transmission Performance:
Performance: 62.5/125um
(850/1300nm)
50/125um
(850/1300nm)
Singlemode
(1310/1550nm)
Maximum Attenuation (dB/Km): 3.5/1.0 3.5/1.5 0.4/0.3
Minimum LED Bandwidth (MHz*Km): 200/500 500/500 -
Gigabit Ethernet Distance: 300/550 600/600 5000
 
Ordering Information:
Item # Description
9410XXX Loose Tube Single-mode Non-Armored
9460XXX Loose Tube Multimode 62.5/125um Non-Armored
9461XXX Loose Tube Multimode 50/125um Non-Armored
 
Indoor Fiber Cable      
 
Multifiber cables utilizing 900 µm tight-buffered fibers surrounded by dielectric strength members and a flame-retardant outer jacket. These cables meet the application requirements of the National Electrical Code® (NEC® Article 770) and are OFNR and FT-4 listed. These cables are ideal for intrabuilding cabling including riser shafts, wiring closets, and workstations.
 
Features and Benefits:
  • Utilizes 900 µm buffered fibers enabling easy, consistent stripping
  • Available in multimode (62.5µm, 50 µm) and single-mode.
  • All-dielectric construction requires no grounding and bonding
  • Meets application requirements of the National Electrical Code (NEC® Article 770)
  • Listed OFNR and FT-4
 
Applications:
  • These cables are used in intrabuilding backbone and horizontal installations in riser and general purpose environments.
 
 
Mechanical Specifications
Operating Temperature: -20ºC to + 70ºC
Storage Temperature: -40ºC to + 70ºC
Approvals and Listings: NEC "OFNR", CSA "FT-4"
Flame Resistance: UL-1666 (for riser and general building applications)
 
Fiber Count Nominal Outer Diameter
mm (in)
Nominal Cable Weight
Kg/km
(lb/ft)
Central Member Maximum Tensile Load Minimum Bend Radius
Short Term
N (lbf)
Long Term
N (lbf)
Loaded
cm (in)
Installed
cm (in)
Single Layer
2 4.7 (0.19) 18 (12) Y 800 (180) 200 (45) 7.1 (2.8) 4.7 (1.9)
4 4.8 (0.19) 21 (14) Y 1000 (225) 300 (68) 7.2 (2.8) 4.8 (1.9)
6 5.3 (0.21) 23 (16) Y 1000 (225) 300 (68) 8.0 (3.1) 5.3 (2.1)
8 6.0 (0.24) 32 (21) G 1400 (315) 440 (99) 8.9 (3.5) 6.0 (2.3)
10 6.4 (0.25) 39 (26) G 1400 (315) 440 (99) 9.5 (3.7) 6.4 (2.5)
Dual Layer
12 (9/3) 6.1 (0.24) 32 (22) Y 1115 (250) 372 (84) 9.9 (3.9) 6.1 (2.4)
14 (10/4) 6.4 (0.25) 36 (24) Y 1500 (338) 500 (113) 10.8 (4.3) 6.4 (2.5)
16 (11/5) 6.6 (0.26) 39 (26) Y 1639 (369) 546 (123) 9.9 (3.9) 6.6 (2.6)
18 (12/6) 7.2 (0.28) 46 (31) Y 1775 (400) 592 (133) 10.8 (4.3) 7.2 (2.8)
20 (13/7) 7.4 (0.29) 48 (32) Y 1800 (405) 600 (135) 11.0 (4.3) 7.4 (2.9)
22 (14/8) 7.4 (0.29) 52 (35) Y 1900 (428) 633 (143) 11.1 (4.4) 7.4 (2.9)
24 (15/9) 7.8 (0.31) 55 (37) JY 1900 (428) 633 (143) 11.7 (4.6) 7.8 (3.1)
Central member Types: Y= Yarn, JY= Jacket Yarn, G= Glass Reinforced Plastic (GRP), JG= Jacketed GRP Fiber arrangement in dual layer design is shown in parentheses.
Example: (9/3) = 9 outside fibers around 3 inner fibers.
 
Transmission Performance:
Performance: 62.5/125um
(850/1300nm)
50/125
(850/1300nm)
Singlemode (1310/1550nm)
Maximum Attenuation (dB/Km): 3.5/1.0 3.5/1.5 1.0/0.75
Typical Attenuation (dB/Km): 3.0/1.0 3.0/1.0 0.5/0.4
Minimum LED Bandwidth (MHz*Km): 200/500 500/500 -
Minimum RML Bandwidth (MHz*Km): 220/- - -
Gigabit Ethernet Distance: 300/550 600/600 5000
 
Ordering Information:
Item # Description
9530XXX Indoor Tight Buffer Multimode 62.5/125um
9531XXX Indoor Tight Buffer Multimode 50/125um
9580XXX Indoor Tight Buffer Singlemode
 
Outdoor Armored Fiber Cable
 
Features and Benefits:
  • Small, lightweight armored design for quicker cable preparation and termination.
  • Innovative cable water-blocking technology eliminates the need for traditional flooding compound, providing more efficient and craft-friendly cable preparation, particularly in mid-span and/or taut access applications.
  • Available in multimode (62.5um, 50um) and single-mode.
  • Standard 3.0 mm buffer tube size reduces the number of access tools required by craftsperson.
  • SZ-stranded, loose tube design isolates fibers from installation and environmental rigors.
  • Medium density PE jacket is rugged, durable, and easy to strip.
 
Applications:
  • Interbuilding backbones in aerial, duct, and direct buried installations
 
Mechanical Specifications
Maximum Tensile Loading: Installation: 2700N (600 lbf)
Long Term Installed: 890 N (200 lbf)
Operating Temperature: -40ºC to +70ºC
Storage Temperature: -40ºC to +70ºC
 
Fiber Count Number of Tubes Nominal Weight
Kg/Km
(lb/1000ft)
Nominal Outer Diameter
mm (in)
Minimum Bend Radius
Loaded
cm (in)
Installed
cm (in)
2 - 24 2 145 (97) 12.3 (0.5) 18.5 (7.3) 12.3 (4.8)
 
Mechanical Specifications:
Performance: 62.5/125um
(850/1300nm)
50/125um
(850/1300nm)
Singlemode
(1310/1550nm)
Maximum Attenuation (dB/Km): 3.5/1.0 3.5/1.5 0.4/0.3
Minimum LED Bandwidth (MHz*Km): 200/500 500/500 -
Gigabit Ethernet Distance: 300/550 600/600 5000
 
Ordering Information:
Item # Description
9430XXX Loose Tube Single-mode Armored
9480XXX Loose Tube Multimode 62.5/125um Armored
94810XX Loose Tube Multimode 50/125um Armored
 
Fiber Connectors
 
ST Connectors
 
Features:
  • Fiber Application: Multimode or Singlemode (see part numbers)
  • Fiber Type: Simplex
  • Compatible with all ST connectors
  • Bayonet coupling mechanism
  • High Performance zirconia ferrule
  • PC ferrule with 20mm radius fast polishing
 
Specifications:
Insertion Loss:
  • Single Mode < 0.3dB
  • Multi Mode < 0.5dB
Return Loss:
  • Single/Multi Mode <40dB SPC
  • Single/Multi Mode >60dB angle PC
SC Connectors
 
Features:
  • Fiber Application: Multimode or Singlemode (see part numbers)
  • Fiber Type: Simplex
  • Compatible with all SC connectors
  • High Precision mechanical dimension
  • High Performance zirconia ferrule
 
Specifications:
Insertion Loss:
  • Single/Multi Mode < 0.2dB
 
Applications:
  • Data Transmission
  • Measurement equipment
  • Telecommunications networks
  • Local Area Networks
 
Durability:
  • Single/Multi Mode <0.2dB after 500 matings
 
Operation Temperature:
  • Single/Multi Mode: -40º C ~ +80º C
 
Ordering Information:
Item# Description Type Fiber Application Fiber Type
312167M ST Ceramic Connector ST Multimode Simplex
312168M ST Ceramic Connector ST Singlemode Simplex
321175M SC Connector SC Multimode Simplex
321176M SC Connector SC Singlemode Simplex
 

 

Site designed and hosted